July 7, 2026
Electric Energy Jobs

Protection and Control Design Engineer

Organization:
Evergy
Region:
Canada, Kansas, Topeka
End of contest:
July 27, 2026
Type:
Full time
Category:
Protection & control
Description
JOB TITLE: Protection and Control Design Engineer 

REQUISTION: TRA00ZP
DEPARTMENT: Transmission Engineering - Substation Protection & Control - Wichita Service Center or Topeka General Office
LOCATION: Wichita, KS
Topeka, KS
PAY GRADE:  (Min-Mid-Max)  
Engineer I: $68,500 - $85,600 - $102,700
Engineer II: $83,600 - $104,500 - $125,400
Staff Engineer: $93,400 - $116,800 - $140,200
Sr. Engineer: $94,600 - $126,100 - $157,600
Lead Engineer: $111,400 - $148,500 - $185,600

Scheduled Work Hours: Monday - Friday, 8:00 a.m. - 5:00 p.m. (Other hours as required)

Position Overview:

Under the direction of the Manager, Protection and Control Engineering performs various technical studies and engineering designs to ensure the appropriate controls systems and protection schemes are utilized on the company's electric grid. The team works closely with other Technical Operations groups, Electric Distribution Engineering, System Planning, Generation Services, and Marketing in assisting with a wide variety of technical issues. The group assists in troubleshooting any protection challenges that appear. Initial duties will include familiarization with the engineering documents and drawings.

Summary of Primary Duties and Responsibilities:
    Design protective relay systems, metering, and SCADA by referencing standards, past projects, new research, regulations, and system requirements in order to ensure reliability and safety
    Perform design relating to the company's electric substations, transmission lines, and generation equipment that ensures the proper controls systems and fault protection schemes
    Specify substation protective equipment based on required schemes and standards 
    Familiar with specifying substation equipment using substation ratings (e.g., bus, ground mat, switches, power circuit breakers, transformers, relay panels, instrumentation, capacitor banks, reactor banks) to ensure the system is reliable
    Gather and analyze system ratings (e.g., voltage, power ratings, ampacity, system impedance, CT ratios, and relay settings) by researching substation current conditions and configurations to provide data to reporting agencies (i.e., SPP, NERC, FERC) and meet new system requirements
    Develop relay one-line diagrams by utilizing relevant information specified by other groups and standards
    Produce detailed system protection and control project scopes and cost estimates to assist in multi-year projects and budget planning by using data from previous projects, bids, and research in order to ensure accuracy and completion of tasks on time and on budget
    Support both operations and construction personnel as needed in troubleshooting, failure analysis, mis-operations, testing assistance, commissioning assistance, and other technical duties by analyzing data and providing findings in order to resolve problems (e.g., equipment failures, construction issues, drawings, event reports)
    Prepare and study technical drawings and specifications of protection systems and equipment to ensure that installation and operations conform to requirements (e.g., Company, protection, code)
    Create alternative system designs by utilizing engineering principles, knowledge, and experience in order to improve system performance
    Direct designers and technicians by reviewing work and monitoring progress in order to ensure compliance with safety and regulations
    Act as a technical resource for internal customers by answering questions and providing information in order to support Company projects
    Visit project sites to collect design information, troubleshoot, and ensure project commissioning
 

 

 

Education and Experience:
Requires a Bachelor's degree in electrical engineering from an ABET accredited program. The preferred candidate will have utility experience directly related to electric substation, generation, and transmission line equipment control and fault protection systems.
    Engineer I -  Entry level, no experience necessary
    Engineer II -  2 or more years of engineering experience
    Staff Engineer -  4 or more years of engineering experience
    Sr Engineer - Typically possesses 8 or more years of engineering experience and an active member of a recognized industry committee or published in recognized technical journals or at minimum has two related career experiences or clearly demonstrated team leadership abilities on critical projects.  
    Lead Engineer - Typically possesses 14 or more years of engineering experience, demonstrate specialized expertise in key areas and meet requirements of Sr. Engineer.  Professional Engineer Licensed preferred.  

Skills, Knowledge and Abilities:
A successful candidate needs knowledge of basic engineering principles and advanced mathematics. The highly required knowledge and skills in electric power engineering including:
    Understanding of schematic, wiring, and connection diagrams 
    Knowledgeable of the different zones of protection schemes within a substation
    Ability to develop elementary schematic drawings and wiring connection prints using design principles
    Knowledge of fault analyses studies, power system per unit calculations, relay settings calculations, and protective relay settings files, is preferred  
    Ability to read and develop the logic diagrams for protective relays 
    Having experience using ASPEN One-Liner or an equivalent fault analysis software, is preferred
    Experience utilizing communication relay schemes, such as directional carrier blocking and permissive overreach transfer trip, is preferred
    Ability to perform coordination studies for various voltage levels, is preferred
    Requires the ability to learn major power systems in a timely fashion
    Awareness of Transmission, Distribution, and Generation system relays and associated protection schemes. 
    Knowledge of NERC system protection standards, is preferred 
    Must be dependable, self-motivated, and detail-oriented while having excellent organizational and proofreading skills  
    Must possess the ability to work and communicate effectively with other company personnel 
    Proficiency in word processing, spreadsheets, and databases  
    Must be able to handle multiple priorities while operating efficiently and effectively in high stress environment

Licenses, Certification, Bonding and/or Testing:
Valid driver's license required. Professional Engineering registration is desirable but not required.

Read the full posting.

Contact

Evergy



Kansas City

Missouri États-Unis

www.evergyinc.com